5E Series Fluorine/Chlorine Analyzer

  • CKIC 5E Series Fluorine/Chlorine Analyzer
  • CKIC 5E Series Fluorine/Chlorine Analyzer
  • CKIC 5E Series Fluorine/Chlorine Analyzer
  • CKIC 5E Series Fluorine/Chlorine Analyzer

    5E Series Fluorine/Chlorine Analyzer is used to determine the fluorine and chlorine in coal or other combustibles by combustion hydrolysis method(Ion selective electrode method for F and Potentiometric titration method for CI), which is widely applied in coal-fired plants, coal mines, steel plants, petrochemical industry, etc.

    Please leave your E-mail address before download the product PDF. Your cooperation is appreciated.

    Warm prompt: Please make sure you entered a correct E-mail address. We will send you relevant information and product quotation regularly.

    • Features
    • Specification
    • Spare parts
    • Case

    Models Available:
    5E-FL2350 to test Fluorine&Chlorine contents
    5E-FT2301 to test Fluorine content
    5E-CLT2311 to test Chlorine content

    Features:High Automation Automatic analysis process available after sample loading.

    High Efficiency
    Two sample analyses for each batch and continuous analysis available.

    High safety Assurance
    Unattended operation with the protection of lack or overflow of water level 

    Flexible Layout
    No water tap is required around the instrument as it is equipped with water tank.

    Model 5E-FL2350
    5E-FT2301 5E-CLT2311
    Conforms to Method Fluorine:GB/T 4633, ISO 11724, AS 1038.10.4
    Chlorine:GB/T 3558, ASTM D6721, ISO 587, SN/T 3596
    Measuring Range Fluorine:20-2000ug/g Chlorine:0.003-0.4%
    Sample Mass 0.5 g
    High Temp Furnace Precision 1100 ±10℃
    Analysis Time 1. Decomposition 35mins
    2.Calibration of electrode parameters available to calibrate when decomposing the first batch of samples and not calculated to total analysis time
    3. Titration Fluorine: 20 mins  Chlorine: 20 mins
    For dual sample analysis: 75 mins
    For continuous analysis: 20 mins/ sample (average)
    Sensitivity of Electrode Potential 0.1mV
    Minimum Filling of Injection Pump 50 uL
    Accuracy Within uncertainty range of standard sample
    Repeatability 15ug/g(Fad≤150ug/g), 10%(Fad>150ug/g), 0.010% (Clad)
    Power Supply Single phase, AC220V±10%, 50/60 Hz, ≤3.5 kW
    Net Weight Analysis Unit:130kg, Reservoir:30kg
    Dimension (L×W×H) Analysis Unit: 1400mm×600mm×610mm
    Reservoir: 900mm×500mm×510mm